CONTACT: distributors | physicians | aesthetic profeSsionals | patients

HOME CLINICAL TECHNOLOGY SYSTEM & ACCESSORIES BEFORE & AFTER DISTRIBUTIOn programs

HERE'S WHAT DOCTORS ARE SAYING...

"the killer app?

I had only 2 KONTUR MD treatments myself initially and can certainly see a difference! I would never have needles stuck in me or laser performed on my face. The KONTUR MD MultiPolar RF device from CARISMED in Germany, which we just started to use, is a very safe, pleasant treatment with reasonable, immediate results at a reasonable price for the client and no consumable costs for the doctor. Name me one other treatment that does that! Plus your nurse/receptionist can do it for you. You get an initial heat sensation followed by a friming, tightening and tingling feeling for the next day or two. The initial effect wears off and then you get a more lasting effect after 8 weeks or so. Throw in a 2 minute peel afterwards and the girls are very happy. Even if the outcome is harder to quantify for the clinician (and perhaps more subjective or less obvious to explain to the client), compared to simply using Botox, fillers or Vaser - we found that offering a new, more comprehensive menu of choices which combines the KONTUR MD RF procedure + Botox and fillers has picked a lot of interest with our patients, made our clinic more cutting-edge and innovative, and it has tremendously improved the immediate visible outcomes. Altogether, this certainly has also helped improving our revenues per visit / patient as well. At our clinic in Heathrow Airport, where we service a large number of flight attendants, we've started offering 10 min 'taster' sessions for £40 on the jowls/jawline. This saves much explaining about the technology and tissue reaction. They usually book in for a series of treatments after that.
What we call now: "the killer app!"

Dr Colin Lyons, MRCGP, DRCOG, Dipl Anaes, Dipl Ther, Dipl Derm MSc.


I used the Carismed (Karlsruhe, Germany) Kontur MD MultiPolar RF device over the last number of months for deep dermal heating to promote neocollagenesis and ultimately tighten skin.  We treated over 21 patients, 4-6 times each, at 1 week intervals.

The medium handpiece was used primarily in automatic mode at 1MHz to target the most superficial tissues.  To target the deeper tissues (ie. Subcutaneous fat) for body contouring and cellulite reduction, the 0.75MHz and 0.5MHz frequencies would seem to be more appropriate.  In addition, the large handpiece is preferred for deeper heating since the greater distance between poles sends the electric current deeper into the tissues. 

The treatments were extremely well tolerated by all patients, and experienced as an increasing warmth over the treated areas.  As the treatment progressed, skin temperature was monitored using an infrared hand-held thermometer.  The target skin temperature was 40-42 degrees celsius.  A thin layer of glycerin 75-100% was applied to cleansed skin before the treatment commenced.

Treatments were performed in automatic mode, 1Hz frequency, at 70-100% intensity.  Treatment times were approximately 12-15 minutes for one side of the face and neck.  After the treatment, the patients’ skin was warm and erythematous.  Some immediate skin contraction and oedema produced a transient improvement in rhytids.  After 4-6 treatments, almost all patients showed a definite improvement in skin roughness as measured on a three-dimensional skin imaging device (Antera 3D, Miravex, Dublin).  All analytic measurements are real improvements after the final 6th treatment, and not just an immediate effect of the generated heat.
In average, the analyses show approximately 20-30% improvement in skin roughness after 6 treatments.

For body applications, the large handpiece and lower frequencies were used to heat the fat.  The tunable nature of the Kontur MD device enables tailored treatments depending on the indication and treatment sites.  This widens the applications from a skin tightening device to a device that could provide contouring through tightening and volume reduction.

Note:  A reduction in intensity or treatment time over bony prominences is recommended.  Two patients sustained minor burns over the chin and cheekbone following treatment at 1MHz with the medium handpiece.

Peter M. Prendergast MB MRCSI
President, European College of Aesthetic Medicine


"The new Multi Polar RF Kontur MD device uses a new energy diffusion concept called
DVTP (for Deep Volumetric Thermal Profile). We can assume that these quick changes of the frequencies, preset for exclusive use in treatment of the larger body areas with bigger fat deposits, are building a unique profile of penetration to the thermal energy which should safely go deeper down to target the adipose tissue layers more efficiently. "

Dan Castro MD, FACS
Professor, Head And Neck Surgery
Former Professor at UCLA School of Medicine

 


"Using the KONTUR MD, I consistently have noticed very good results in body-contouring treatments and skin rejuvenation and facial tightening as well as the firming and a significant slimming of the body. The KONTUR MD system is allowing for virtually unlimited freedom of choice of parameters to fit each individual patient and body area. The device unique RF system using 3 different frequencies, gave me the opportunity to achieve better results on different depths of tissue. This function is extremely useful in the fight against cellulite and excess fat tissue.

Marzena Lorkowska-Precht, MD
Anti-aging and aesthetic medicine Member of the American Academy of Anti-Aging Medicine Member of the World Society of Anti-Aging Medicine Member of the Association of Aesthetic Dermatology and the Polish Society of Anti-Aging Medicine.

 

 





© CARISMED CORP 2011-2012 (US COMPANY) ALL RIGHTS RESERVED contact us
MANUFACTURED EXCLUSIVELY FOR CARISMED IN GERMANY BY TUR ISO13485